Endovascular stent-graft placement for the management of a traumatic axillary artery pseudoaneurysm: A case report


Oktar G. L., Balkan M. E., Akpek S., Ilgit E. T.

Vascular and Endovascular Surgery, cilt.36, sa.4, ss.323-326, 2002 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 36 Sayı: 4
  • Basım Tarihi: 2002
  • Doi Numarası: 10.1177/153857440203600412
  • Dergi Adı: Vascular and Endovascular Surgery
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.323-326
  • Gazi Üniversitesi Adresli: Evet

Özet

A 24-year-old woman with a right infraclavicular gunshot wound developed an axillary artery pseudoaneurysm. She was successfully treated by using a 5 cm Hemobahn stent-graft with a diameter of 6 mm. Postimplantation arteriography revealed normal flow through the axillary artery without evidence of leakage of contrast medium. Five months after the procedure, stenoses developed within the stent-graft owing to intimal hyperplasia and were treated by balloon angioplasty. The patient has been followed up symptom-free for 6 months after the second procedure.