Effect of cartilage thickness mismatch in osteochondral grafting from knee to talus on articular contact pressures: A finite element analysis


Creative Commons License

Kilicaslan O. F., Levent A., ÇELİK H. K., Tokgoz M. A., Kose O., Rennie A. E. W.

JOINT DISEASES AND RELATED SURGERY, vol.32, no.2, pp.355-362, 2021 (SCI-Expanded) identifier identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 32 Issue: 2
  • Publication Date: 2021
  • Doi Number: 10.52312/jdrs.2021.41
  • Journal Name: JOINT DISEASES AND RELATED SURGERY
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus, TR DİZİN (ULAKBİM)
  • Page Numbers: pp.355-362
  • Keywords: Cartilage, mosaicplasty, osteochondral grafting, osteochondral lesions, talus, tibiotalar contact pressure, ANKLE STABILITY, TRANSPLANTATION, LESIONS, TALAR, BONE, DEFECTS, JOINT, SIZE
  • Gazi University Affiliated: No

Abstract

Objectives: The aim of this study was to investigate the effect of cartilage thickness mismatch on tibiotalar articular contact pressure in osteochondral grafting from femoral condyles to medial talar dome using a finite element analysis (FEA).