Experimental investigation of RC shear walls with openings under cyclic loading repaired with externally bonded CFRP strips


ÖZDEMİR A., KOPRAMAN Y.

Archives of Civil and Mechanical Engineering, vol.24, no.1, 2024 (SCI-Expanded) identifier identifier

  • Publication Type: Article / Article
  • Volume: 24 Issue: 1
  • Publication Date: 2024
  • Doi Number: 10.1007/s43452-023-00828-y
  • Journal Name: Archives of Civil and Mechanical Engineering
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Central & Eastern European Academic Source (CEEAS), Compendex, INSPEC
  • Keywords: CFRP strip, Cyclic loading, Earthquake, Repair, Shear wall with openings
  • Gazi University Affiliated: Yes

Abstract

A total of 9 real scale reinforced concrete shear walls were produced, 3 of them being the reference, representing the basement floor of a reinforced concrete building. These 9 shear walls produced, 3 wall are fully filled, 3 of them have window openings and 3 of them have door openings. The RC shear walls were exposed to displacement-controlled reversed cyclic lateral loading. In the experiments that damaged the experimental specimens, loads up to 0.5% story drift ratio for moderate damage and 1.0% story drift ratio for heavy damage were applied. Within the scope of the experimental study, the damage distributions of the tested nine RC shear walls were examined in detail, and the strengthening technique was developed using CFRP strip and CFRP fan-type anchors. The performance of damaged RC shear walls after using the devised repair method was analysed. The study's findings revealed that the repair method created by employing CFRP strips to restore moderately damaged RC shear walls with and without apertures was well enough successful in restoring the shear walls' performance levels.