JOURNAL OF PROSTHETIC DENTISTRY, cilt.131, sa.3, 2024 (SCI-Expanded)
Statement of problem. The adaptation of digitally produced crowns is affected by the design software program and manufacturing method. The effect of artificial intelligence (AI) software program design on the adaptation of the crowns is unclear and comparative evaluations should be documented. Purpose. The purpose of this study was to assess the marginal and internal gaps, the absolute marginal discrepancies, and the 3 -dimensional (3D) discrepancy volumes of the resin -based milled and 3D printed crowns for primary teeth designed with computer -aided design (CAD) and AI software programs by using microcomputed tomography (pCT). Material and methods. A total of 40 resin -based esthetic crowns were produced for a prepared typodont tooth (right mandibular primary second molar) according to the design software program (CAD and AI) and manufacturing method (milling and 3D printing) (n=10). Four experimental groups were generated as CAD -milled, CAD -3D printed, AI -milled, and AI -3D printed. The marginal, axial, and occlusal gap values, the absolute marginal discrepancies, and the 3D discrepancy volumes of the specimens were measured by using pCT. The data were analyzed by using 2 -way ANOVA and the Tukey HSD tests (alpha=.05). Results. The lowest value for the marginal gap (54 +/- 43 pm) was observed in the CAD -milled group and the marginal gap value of the AI -3D printed group was significantly lower than the AImilled group (P<.05). The lowest value for the axial gap (63 +/- 7 pm) was observed in the AI -3D printed group, and the highest value (145 +/- 58 pm) was observed in the CAD -milled group; the result for the occlusal gap value was opposite. The highest absolute marginal discrepancy value was observed in the CAD -milled group. The 3D discrepancy volumes increased in the order of the CAD -3D printed, AI -milled, CAD -milled, and AI -3D printed groups. Conclusions. The marginal and internal gap values of the resin -based crowns were affected by the design software program and manufacturing method; however, tested groups showed clinically acceptable gap values.