Architectural-Structural Integration in Seismic Retrofitting of Prefabricated Reinforced Concrete Industrial Buildings: Damage Mechanisms, Intervention Approaches, and Design Decisions
Innovative Approaches and Scientific Studies in Architecture, Planning and Design, Murat Kılıç, Editör, Duvar Yayınları, İzmir, ss.46-75, 2026
- Yayın Türü: Kitapta Bölüm / Araştırma Kitabı
- Basım Tarihi: 2026
- Yayınevi: Duvar Yayınları
- Basıldığı Şehir: İzmir
- Sayfa Sayıları: ss.46-75
- Editörler: Murat Kılıç, Editör
- Gazi Üniversitesi Adresli: Evet
Özet
Industrial buildings made of prefabricated reinforced concrete are commonly used as factory and warehouse rooms for single and multiple storey buildings in Turkey. However, these structures can develop extensive joint damage, joint column bases can collapse, roof systems can fail, façades can come apart, etc. after major earthquakes, regardless of the main advantages of such buildings, i.e., relatively short construction periods and ease of modularity. As one of the effects of a retrofitting strategy is to alter the structural performance but also the spatial layout, the design aspects of the exterior walls, layout of internal facilities, uninterrupted functioning, and the overall life cycle value, the paper presents four types of interventions: upgrading of panel-frame connections, wrapping columns, addition of energy-dissipating braces/dampers, and prestressed complementary frames. The analysis consists of a narrative synthesis of peer-reviewed works, earthquake aftermath data collected in the field and official technical standards. The supporting evidence was grouped into on-site inspections, laboratory studies, simulated models, and specifications, and, methods were analyzed according to damage modes, efficiency indexes, level of architectural changes, and preconditions for the method application. While the literature describes model-specific drift reductions in jacketing as leading to 54-72% and, lead extrusion dampers as to 40-90%, they were not directly translated into an overall ranking of superiority mainly because of different structural configurations and shake characteristics. The outcome of the discussion is also that the architects/structural engineers/clients decision making on the spatial planning aspects of the building, the compatibility of the movements of the building exterior with the interventions adopted, the duration of the period of interruption of production, and the accessibility condition for the maintenance personnel should be evaluated simultaneously with the technical matters like the transfer of loads and the security of the joint. The decision framework on architectural-structural issues that has been outlined in this paper was not an instrument to carry out a design verification. On the other hand, it is a form of qualitative assessment to guide more detailed investigations on a case-by-case basis.