Analytical and Numerical Calculations of the Parasitic Parameters of a High-Voltage HighFrequency Transformer


Shan A., ÖZDEMİR M. A., TAMYÜREK B., Aydin E., Aydemir M. T.

19th IEEE International Conference on Compatibility, Power Electronics and Power Engineering, CPE-POWERENG 2025, Antalya, Türkiye, 20 - 22 Mayıs 2025, (Tam Metin Bildiri) identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Doi Numarası: 10.1109/cpe-powereng63314.2025.11027261
  • Basıldığı Şehir: Antalya
  • Basıldığı Ülke: Türkiye
  • Anahtar Kelimeler: ANSYS, high frequency transformer, leakage inductance, Litz wire, parasitic capacitance
  • Gazi Üniversitesi Adresli: Evet

Özet

High-voltage high-frequency (HVHF) transformers are crucial to many modern power electronics systems. Determining their performance and efficiency of their parasitic parameters such as parasitic capacitance leakage inductance and is vital. Most of the time, these parameters are analysed separately but, for accurate transformer optimization and design, a combined analysis is very crucial. This paper explains both the leakage and parasitic capacitance calculations for an HVHF transformer designed and built in our laboratory. Based on the established analytical methods, these parasitic parameters are calculated considering the geometrical and material properties of the transformer. The results are validated numerically using finite element analysis. Transformer losses are also calculated.