Journal of Stomatology, Oral and Maxillofacial Surgery, cilt.125, sa.5, 2024 (SCI-Expanded)
Objectives: Dynamic analysis of chewing impact on the stability of rigid fixation techniques following Le Fort I osteotomy has not been investigated in the previous literature. The aim of the present study was to evaluate segmental displacement and von Mises (VM) stress values on the fixation devices following different amounts of Le Fort I advancements under dynamic loading conditions. Materials and methods: The 3D finite element models simulating 3, 5 and 8 mm advancement of maxilla at the Le Fort I level were generated using CBCT scan data. The models included two anterior L plates and two posterior I plates fixations bilaterally. Dynamic finite element analysis was performed to evaluate their biomechanical behavior against chewing cornflakes bio. Von Mises stresses and displacement values on three points were calculated. Results: Calculations were made in a time of 38, 40 and 40.5 ms for 3, 5 and 8 mm advancement models, respectively. As the advancement increased, stress values on the plates and displacement values in the D1 (intersection of the apex of the canine tooth with the osteotomy line), D2 (the most prominent point of zygomatic buttress on the osteotomy line), and D3 (intersection of the midline of the second molar tooth with the osteotomy line) points increased. The lowest stress and displacement values were found in the 3 mm advancement model. As advancement increased, the highest values were found in the I plates. The stress levels on the plates and screws remained within safe limits. Conclusions: The von Mises stresses and displacement values tend to increase in according with the amount of advancement. More stress is transferred to posterior I plates and screws under dynamic forces.