The influence of freezing-thawing cycles on the capillary water absorption and porosity of concrete with mineral admixture


GÖNEN T., YAZICIOĞLU S., DEMİREL B.

KSCE JOURNAL OF CIVIL ENGINEERING, cilt.19, sa.3, ss.667-671, 2015 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 19 Sayı: 3
  • Basım Tarihi: 2015
  • Doi Numarası: 10.1007/s12205-012-0207-7
  • Dergi Adı: KSCE JOURNAL OF CIVIL ENGINEERING
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.667-671
  • Anahtar Kelimeler: capillary water absorption, freezing-thawing, mineral admixture, porosity, ultrasonic pulse velocity, SILICA FUME CONCRETE, FLY-ASH CONCRETE, COMPRESSIVE STRENGTH, CARBONATION, RESISTANCE, PERMEABILITY, PERFORMANCE, DURABILITY, SORPTIVITY, HYDRATION
  • Gazi Üniversitesi Adresli: Evet

Özet

The main objective of this experimental study is to determine which of the effective parameter among ultrasonic pulse velocity, compressive strength, capillary water absorption and porosity during freezing and thawing on concrete produced with mineral admixtures. The specimens were exposed to 25, 50, 75 and 100 freezing-thawing cycles after 28 curing days. The results showed that among the measured parameters, capillary water absorption was the most affected parameter from freeze-thaw cycles.