Analyzing elevator use for evacuation efficiency of high-rise buildings in normal conditions: The Case of Is Tower / Yüksek binaların normal durum tahliye etkinliğinde asansör kullanımının analizi: İş kule örneği


Creative Commons License

Satır M. S., Topraklı A. Y.

JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, cilt.38, sa.3, ss.1493-1504, 2023 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 38 Sayı: 3
  • Basım Tarihi: 2023
  • Doi Numarası: 10.17341/gazimmfd.1055882
  • Dergi Adı: JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Art Source, Compendex, TR DİZİN (ULAKBİM)
  • Sayfa Sayıları: ss.1493-1504
  • Anahtar Kelimeler: High-rise Buildings, Elevator, Stair, Egress, Normal Evacuation
  • Gazi Üniversitesi Adresli: Evet

Özet

Artan kentleşme ile yoğunlaşan kentlerde sınırlı alanın daha etkin kullanılabilmesi amacıyla yüksek yapıların sayısı gün geçtikçe artmaktadır. İstanbul’un dünyada en çok yüksek bina bulunan 9. şehri olması, yüksek yapı konusunda ülkemizin yerini ve konuya verilmesi gereken önemi göstermektedir. Yüksek binalarda karşılaşılan en büyük problemlerden birisi, uzun tahliye süreleridir. Artan kat sayısı ile birlikte uzayan tahliye rotası tahliyeyi zorlaştırmaktadır. Bu çalışmada, yüksek binaların tahliyesinde uzun yıllardır tartışılan ve araştırılan asansör ile tahliye konusu incelenmiştir. Dünya’da asansör ile tahliyeye izin veren standart ve yönetmelikler dile getirilmiştir. İstanbul’da yer alan ve yakın geçmişte Türkiye’nin en yüksek binası olma unvanını taşımış İş Kule binası üzerinden yapılan araştırmada, bina modeli simülasyonlarla analiz edilmiştir. Yapılan çalışmada asansör kullanımının, binanın tahliye süresine etkisi incelenmiştir. Oluşturulan 5 farklı senaryoda, binadaki her katın kullanıcılarının hangi oranda merdiven ve asansör kullanımıyla en kısa tahliye süresine ulaşılabildiği incelenmiştir. Elde edilen bulgular sonucu, binanın her katındaki kullanıcıların %25’inin asansörle, kalan %75’lik kısmın ise merdivenle tahliye edilmesiyle en kısa tahliye süresine ulaşıldığı görülmüştür. Bu senaryoda, sadece merdiven kullanımına göre tahliye süresinde yaklaşık %18’lik bir kısalma gözlenmiştir. Ayrıca binanın tahliye elemanlarının en etkin şekilde kullanılmasına engel olan mimari etmenlerden bahsedilmiştir.

Purpose: One of the biggest problems encountered in high-rise buildings is long evacuation times. With the increasing number of floors, the lengthening evacuation route makes evacuation difficult. In this study, the issue of evacuation by elevator, which has been discussed and researched for many years in the evacuation of high-rise buildings, is examined. In the study, the effect of the use of elevators on the evacuation time of the building was investigated.

 

Theory and Methods:

In this study, which the effect of the use of elevators on the evacuation time of high-rise buildings was examined, 5 different scenarios modeled. It was examined to what fraction of the occupants of each floor should use the stairs and elevators to reach the shortest evacuation time. In 5 different scenarios, occupants are assigned to use elevators and stairs in 25% increments.

 

Results:

As a result of the simulation, it was observed that the shortest evacuation time was reached when 25% of the occupants on each floor evacuated the building using the elevator and the remaining 75% using the stairs. With this scenario, 18% shorter evacuation time was achieved compared to the scenario which all occupants use the stairs.

 

Conclusion:

It has been observed that the evacuation time can be reduced by 18% with the use of elevators in the evacuation of İş Tower. A longer evacuation time was observed in the elevator-only scenario compared to the staircase-only scenario. The reason for this is that the handling capacity of the stairs of the building is lower than the handling capacity of the elevators. The Round Trip Time should be considered when designing the elevator layout for the upper and lower floors of the building. It has been observed that locating the stair and elevator lobbies together has the effect of extending the evacuation time.