Magneto-Immunoassay for the Detection and Quantification of Human Growth Hormone


Creative Commons License

Ramanaviciene A., Popov A., Baliunaite E., Brasiunas B., Kausaite-Minkstimiene A., TAMER U., ...Daha Fazla

BIOSENSORS-BASEL, cilt.12, sa.2, 2022 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 12 Sayı: 2
  • Basım Tarihi: 2022
  • Doi Numarası: 10.3390/bios12020065
  • Dergi Adı: BIOSENSORS-BASEL
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Agricultural & Environmental Science Database, Applied Science & Technology Source, EMBASE, INSPEC, MEDLINE, Directory of Open Access Journals
  • Anahtar Kelimeler: human growth hormone, gold shell magnetic nanoparticles, sandwich-type colorimetric magneto-immunoassay, GOLD NANOPARTICLES, SURFACE, IMMUNOSENSOR, IMMOBILIZATION
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Gazi Üniversitesi Adresli: Evet

Özet

Physiological and endocrine maintenance of a normal human growth hormone (hGH) concentration is crucial for growth, development, and a number of essential biological processes. In this study, we describe the preparation and characterization of magnetic nanoparticles coated with a gold shell (MNPs-Au). The optimal surface concentration of monoclonal anti-hGH antibodies (m-anti-hGH) on magnetic nanoparticles, as well as conditions that decrease non-specific interactions during the magneto-immunoassay, were elaborated. After the selective recognition, separation, and pre-concentration of hGH by MNPs-Au/m-anti-hGH and the hGH interaction with specific polyclonal biotin-labeled antibodies (p-anti-hHG-B) and streptavidin modified horseradish peroxidase (S-HRP), the MNPs-Au/m-anti-hGH/hGH/p-anti-hGH-B/S-HRP immunoconjugate was formed. The concentration of hGH was determined after the addition of 3,3 ',5,5 '-tetramethylbenzidine and hydrogen peroxide substrate solution for HRP; the absorbance at 450 nm was registered after the addition of STOP solution. The developed sandwich-type colorimetric magneto-immunoassay is characterized by a clinically relevant linear range (from 0.1 to 5.0 nmol L-1, R-2 0.9831), low limit of detection (0.082 nmol L-1), and negligible non-specific binding of other antibodies or S-HRP. The obtained results demonstrate the applicability of the developed magneto-immunoassay for the concentration and determination of hGH in the serum. Additionally, important technical solutions for the development of the sandwich-type colorimetric magneto-immunoassay are discussed.