Detecting the interferences in adrenocorticotropic hormone measurement - three cases reinforcing the efficiency of the complementary clinical and laboratory audit


BARLAS T., YALÇIN M. M., OSMANOV Z., GÜLBAHAR Ö., EROĞLU ALTINOVA A., AKTÜRK M. Y., ...Daha Fazla

Biochemia medica, cilt.34, sa.1, ss.10802, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 34 Sayı: 1
  • Basım Tarihi: 2024
  • Doi Numarası: 10.11613/bm.2024.010802
  • Dergi Adı: Biochemia medica
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Central & Eastern European Academic Source (CEEAS), EMBASE, MEDLINE, Directory of Open Access Journals
  • Sayfa Sayıları: ss.10802
  • Anahtar Kelimeler: adrenal insufficiency, adrenocorticotropic hormone, Cushing’s syndrome, immunoassay, interference
  • Gazi Üniversitesi Adresli: Evet

Özet

Accurate measurement of adrenocorticotropic hormone (ACTH) is crucial in the evaluation of pituitary and adrenal disorders. Although great progress has been achieved in ACTH measurement with immunometric assays, interference may occur and adversely affect the clinical management. The report contributes to compiling the evidence on the clinical challenges with the management of the interferences in the ACTH measurement by presenting three cases: two with clinically overt hypercortisolism and discrepant ACTH concentrations within the reference interval; the third case describes the falsely elevated ACTH in a patient with secondary adrenal insufficiency. In all patients, the results obtained with the two immunometric platforms, chemiluminescence (CLIA) immunoassay (Siemens, Immulite) and electrochemiluminescence (ECLIA) immunoassay (Roche, Cobas), were discordant. Serial dilution of plasma samples revealed nonlinearity. After polyethylene glycol (PEG) precipitation recoveries were less than 22%, 26%, and 3%, respectively, supporting interference. Moreover, a decrease in ACTH concentration after incubation in a heterophile antibody-blocking tube was observed in the second case. In the first case, misinterpretation of ACTH led to inferior petrosal sinus sampling (IPSS), whereas timely detection of assay interference prevented further investigations in other cases. Increasing awareness regarding ACTH interference and comprehensive approach in evaluation could allow timely detection, helping to prevent unnecessary testing and perplexing clinical outcomes.