EFFECT OF STRAIGHT AND ANGLED ABUTMENTS ON THE STRAIN ON A ZIRCONIA CROWN AND IMPLANT IN THE MANDIBULAR SECOND MOLAR REGION: A FEA-BASED STUDY
MATERIALI IN TEHNOLOGIJE, cilt.54, sa.2, ss.251-257, 2020 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 54 Sayı: 2
- Basım Tarihi: 2020
- Doi Numarası: 10.17222/mit.2019.121
- Dergi Adı: MATERIALI IN TEHNOLOGIJE
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Directory of Open Access Journals
- Sayfa Sayıları: ss.251-257
- Gazi Üniversitesi Adresli: Evet
Özet
In a literature search no study evaluating implant-supported posterior restorations using zircon crowns with straight and angled abutments was found. In this study, the stress distribution of a zircon-crown restoration that will be prepared by using an angular and straight abutment in a mandibular second-molar deficiency, under functional forces, stress over zircon crown and environmental tissues of implant will be evaluated using the finite-element analysis (FEA) method. The FEA result showed that the use of straight implants contributes to the lowest stresses. The selection of a straight and angular abutment is very important for the balance of distributed loading.