Load-induced strain analysis in geocell reinforced footing systems


Demirdogen S., GÜRBÜZ A.

Geotextiles and Geomembranes, cilt.53, sa.5, ss.1156-1167, 2025 (SCI-Expanded) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 53 Sayı: 5
  • Basım Tarihi: 2025
  • Doi Numarası: 10.1016/j.geotexmem.2025.05.002
  • Dergi Adı: Geotextiles and Geomembranes
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Compendex, INSPEC, Civil Engineering Abstracts
  • Sayfa Sayıları: ss.1156-1167
  • Anahtar Kelimeler: Bearing capacity, Footing settlement, Geocell, Geosynthetics, Shallow foundation, Strain distribution, Strain gauge
  • Gazi Üniversitesi Adresli: Evet

Özet

In performance-based design, it is crucial to understand deformation characteristics of geocell layers in soil under footing loads. To explore this, a series of laboratory loading tests were carried out to investigate the influence of varying parameters on the strain levels within the geocell layer in a sandy soil under axial strip footing loading. The results were analyzed in terms of maximum strain levels, strain variation along the geocell layer and the correlation between horizontal and vertical strains. In this study, the maximum observed strain levels for geocell-reinforced strip footing systems reached 2.3 % for horizontal (tensile) strain and 1.4 % for vertical (compressive) strain. Furthermore, most strain levels were concentrated within a distance of 1.5 times the footing width from the axis of strip footing. In geocell-reinforced footing systems, the interaction between horizontal and vertical strains becomes a key factor, with the ratio of horizontal to vertical cell wall strains ranging approximately from 1 to 2.5. The outcomes of this study are expected to contribute to the practical applications of geocell-reinforced footing systems.