Short-term graft patency of sequential and Y-graft in open heart surgery with transit time flow measurement
JOURNAL OF CARDIOVASCULAR SURGERY, vol.56, no.5, pp.793-797, 2015 (SCI-Expanded, Scopus)
- Publication Type: Article / Article
- Volume: 56 Issue: 5
- Publication Date: 2015
- Journal Name: JOURNAL OF CARDIOVASCULAR SURGERY
- Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Page Numbers: pp.793-797
- Gazi University Affiliated: Yes
Abstract
Aim. In this prospective study, we aimed to compare flow characteristics and the short term patency of sequential and y-grafts by intraoperative transit time flow measurement.