Evaluation of the effect of two different occlusal splints on maximum occlusal force in patients with sleep bruxism: a pilot study


Karakış D., Doğan A., Bek B.

JOURNAL OF ADVANCED PROSTHODONTICS, cilt.6, sa.2, ss.103-108, 2014 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 6 Sayı: 2
  • Basım Tarihi: 2014
  • Doi Numarası: 10.4047/jap.2014.6.2.103
  • Dergi Adı: JOURNAL OF ADVANCED PROSTHODONTICS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.103-108
  • Anahtar Kelimeler: Occlusal splint, Bruxogard-Soft splint, Occlusal force, Sleep bruxism, Strain-gage, MASTICATORY MUSCLE-ACTIVITY, TEMPOROMANDIBULAR DISORDERS, NOCTURNAL BRUXISM, BITE FORCE, CRANIOMANDIBULAR DISORDERS, STABILIZATION SPLINT, MASSETER MUSCLES, CANINE GUIDANCE, EMG ACTIVITY, APPLIANCES
  • Gazi Üniversitesi Adresli: Evet

Özet

PURPOSE. The occlusal splint has been used for many years as an effective treatment of sleep bruxism. Several methods have been used to evaluate efficiency of the occlusal splints. However, the effect of the occlusal splints on occlusal force has not been clarified sufficiently. The purpose of this study was to evaluate the effect of occlusal splints on maximum occlusal force in patients with sleep bruxism and compare two type of splints that are Bruxogard-soft splint and canine protected hard stabilization splint. MATERIALS AND METHODS. Twelve students with sleep bruxism were participated in the present study. All participants used two different occlusal splints during sleep for 6 weeks. Maximum occlusal force was measured with two miniature strain-gage transducers before, 3 and 6 weeks after insertion of occlusal splints. Clinical examination of temporomandibular disorders was performed for all individuals according to the Craniomandibular Index (CMI) before and 6 weeks after the insertion of splints. The changes in mean occlusal force before, 3 and 6 weeks after insertion of both splints were analysed with paired sample t-test. The Wilcoxon test was used for the:comparison of the CMI values before and 6 weeks after the insertion of splints. RESULTS. Participants using stabilization splints showed, no statistically significant changes in occlusal force before; 3, and 6 weeks after insertion of splint (P>.05) and participants using Bruxogard-soft splint had statistically significant decreased occlusal force 6 weeks after insertion of splint (P<.05). There was statistically significant improvement in the CMI value of the participants in both of the splint groups (P<.05). CONCLUSION. Participants who used Bruxogard-soft splint showed decreases in occlusal force 6 weeks after insertion of splint. The use of both splints led to a significant reduction in the clinical symptoms.