Pulsed beam tests at the SANAEM RFQ beamline


Turemen G., Akgun Y., Alacakir A., Kilic I., Yasatekin B., Ergenlik E., ...Daha Fazla

8th International Particle Accelerator Conference (IPAC), Copenhagen, Danimarka, 14 - 19 Mayıs 2017, cilt.874 identifier identifier

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Cilt numarası: 874
  • Doi Numarası: 10.1088/1742-6596/874/1/012045
  • Basıldığı Şehir: Copenhagen
  • Basıldığı Ülke: Danimarka
  • Gazi Üniversitesi Adresli: Evet

Özet

A proton beamline consisting of an inductively coupled plasma (ICP) source, two solenoid magnets, two steerer magnets and a radio frequency quadrupole (RFQ) is developed at the Turkish Atomic Energy Authority's (TAEA) Saraykoy Nuclear Research and Training Center (SNRTC-SANAEM) in Ankara. In Q4 of 2016, the RFQ was installed in the beamline. The high power tests of the RF power supply and the RF transmission line were done successfully. The high power RF conditioning of the RFQ was performed recently. The 13.56 MHz ICP source was tested in two different conditions, CW and pulsed. The characterization of the proton beam was done with ACCTs, Faraday cups and a pepper-pot emittance meter. Beam transverse emittance was measured in between the two solenoids of the LEBT. The measured beam is then reconstructed at the entrance of the RFQ by using computer simulations to determine the optimum solenoid currents for acceptance matching of the beam. This paper will introduce the pulsed beam test results at the SANAEM RFQ beamline. In addition, the high power RF conditioning of the RFQ will be discussed.